Skip to main content

Privacy Policy

 

Privacy Policy for Power Plant Guruji

At Power Plant Guruji, accessible from https://www.powerplantguruji.in , one of our main priorities is the privacy of our visitors. This Privacy Policy document contains types of information that is collected and recorded by Power Plant Guruji and how we use it.

If you have additional questions or require more information about our Privacy Policy, do not hesitate to contact us.

This Privacy Policy applies only to our online activities and is valid for visitors to our website with regards to the information that they shared and/or collect in Power Plant Guruji. This policy is not applicable to any information collected offline or via channels other than this website. 

Consent

By using our website, you hereby consent to our Privacy Policy and agree to its terms.

Information we collect

The personal information that you are asked to provide, and the reasons why you are asked to provide it, will be made clear to you at the point we ask you to provide your personal information.

If you contact us directly, we may receive additional information about you such as your name, email address, phone number, the contents of the message and/or attachments you may send us, and any other information you may choose to provide.

When you register for an Account, we may ask for your contact information, including items such as name, company name, address, email address, and telephone number.

How we use your information

We use the information we collect in various ways, including to:

  • Provide, operate, and maintain our webste
  • Improve, personalize, and expand our webste
  • Understand and analyze how you use our webste
  • Develop new products, services, features, and functionality
  • Communicate with you, either directly or through one of our partners, including for customer service, to provide you with updates and other information relating to the webste, and for marketing and promotional purposes
  • Send you emails
  • Find and prevent fraud

Log Files

Power Plant Guruji follows a standard procedure of using log files. These files log visitors when they visit websites. All hosting companies do this and a part of hosting services' analytics. The information collected by log files include internet protocol (IP) addresses, browser type, Internet Service Provider (ISP), date and time stamp, referring/exit pages, and possibly the number of clicks. These are not linked to any information that is personally identifiable. The purpose of the information is for analyzing trends, administering the site, tracking users' movement on the website, and gathering demographic information.

Advertising Partners Privacy Policies

You may consult this list to find the Privacy Policy for each of the advertising partners of Power Plant Guruji.

Third-party ad servers or ad networks uses technologies like cookies, JavaScript, or Web Beacons that are used in their respective advertisements and links that appear on Power Plant Guruji, which are sent directly to users' browser. They automatically receive your IP address when this occurs. These technologies are used to measure the effectiveness of their advertising campaigns and/or to personalize the advertising content that you see on websites that you visit.

Note that Power Plant Guruji has no access to or control over these cookies that are used by third-party advertisers.

Third Party Privacy Policies

Power Plant Guruji's Privacy Policy does not apply to other advertisers or websites. Thus, we are advising you to consult the respective Privacy Policies of these third-party ad servers for more detailed information. It may include their practices and instructions about how to opt-out of certain options.

You can choose to disable cookies through your individual browser options. To know more detailed information about cookie management with specific web browsers, it can be found at the browsers' respective websites.

CCPA Privacy Rights (Do Not Sell My Personal Information)

Under the CCPA, among other rights, California consumers have the right to:

Request that a business that collects a consumer's personal data disclose the categories and specific pieces of personal data that a business has collected about consumers.

Request that a business delete any personal data about the consumer that a business has collected.

Request that a business that sells a consumer's personal data, not sell the consumer's personal data.

If you make a request, we have one month to respond to you. If you would like to exercise any of these rights, please contact us.

GDPR Data Protection Rights

We would like to make sure you are fully aware of all of your data protection rights. Every user is entitled to the following:

The right to access – You have the right to request copies of your personal data. We may charge you a small fee for this service.

The right to rectification – You have the right to request that we correct any information you believe is inaccurate. You also have the right to request that we complete the information you believe is incomplete.

The right to erasure – You have the right to request that we erase your personal data, under certain conditions.

The right to restrict processing – You have the right to request that we restrict the processing of your personal data, under certain conditions.

The right to object to processing – You have the right to object to our processing of your personal data, under certain conditions.

The right to data portability – You have the right to request that we transfer the data that we have collected to another organization, or directly to you, under certain conditions.

If you make a request, we have one month to respond to you. If you would like to exercise any of these rights, please contact us.

Children's Information

Another part of our priority is adding protection for children while using the internet. We encourage parents and guardians to observe, participate in, and/or monitor and guide their online activity.

Power Plant Guruji does not knowingly collect any Personal Identifiable Information from children under the age of 13. If you think that your child provided this kind of information on our website, we strongly encourage you to contact us immediately and we will do our best efforts to promptly remove such information from our records.

Popular posts from this blog

BOE Exam ( Boiler Operation Engineer ) Solved Papers Set - 21

Boiler Operation Engineer (BOE) Previous Year Questions With Answer - 21 1. What is the solubility of dissolved gases at boiling or saturation temperature? a) Positive b) Negative c) Zero d) None of the mentioned Ans. c 2. In the deaerator, the feedwater is heated to the saturation temperature by the steam extracted from? a) compressor b) turbine c) pump d) none of the mentioned Ans. b 3. Which of the following type heater is known as deaerator? a) Contact-type open heater b) Contact-type closed heater c) Closed heater d) None of the mentioned Ans. a 4. Where is the deaerator placed in the feedwater system? a) in the beginning b) in the middle c) at the end d) there is no deaerator in the feedwater system Ans. b 5. Which among the following goes to the Vent Condenser along with Oxygen & Carbon dioxide? a) Sodium sulphite b) Carbon monoxide c) Water vapour d) None of the mentioned Ans. c 6. Why is the deaerator not employed in water cooled & moderated nuclear power plant? a) due

Boiler interview questions and answers pdf

 Boiler Operation Engineer Interview Question - 16 Q.No-1. Can the blades of FD fan be replaced by  the ID fan blades?  Ans. Yes, but the power consumption will increase and motor will be unnecessarily overloaded. Q.No-2. What is the function of pitch control mechanism? Ans. To vary the blade angle of FD and ID fan, in order to vary the quantity of air flow across the fan by means of hydraulic servomotor. Q.No-3. For what purpose dampers are used and where these are located ? Ans.  a) Dampers are used to start the FD and ID fan at no load condition b) During maintenance to keep it is isolate condition Q.No-4. Which economizer is best one and Why it so ? Ans. Non steaming type economizer is the best one. Reasons   a.) It enhance the natural circulation b.) Effective utilization of heat carried away by the flue gas is recovered for preheating the air in RAPH  c.) Efficiency of the boiler will increase Q.No-5. What is Natural circulation? How it takes place? Ans. It is defined as t

BOE (Boiler Operation Engineer) Previous Year Exam Questions And Answers Set - 8

Question 1.The capacity of induced draft fan compared to forced draft fan in a boiler is ………. A. Same B. More C. Less D. Depending upon size of boiler Ans. B Question 2.O2 content in atmospheric air on volume basis is ………… A. 21% B. 23% C. 30% D. 78% Ans. A Question 3.Scale is formed on heat transfer surface when……………….. A. Water is acidic B. Water is alkaline C. Water contains dissolved gases D. Water contains dissolved calcium and magnesium salts. Ans. D Question 4.Which one of the following fuel has the highest hydrogen content and lowest sulphur content …………… A. Coal B. Furnace oil C. Natural gas D. LSHS Ans. C Question 5.For boiler water treatment chemical dosing with small discharge at high pressure, pump preferred is ………… A. Centrifugal B. Axil flow C. Propeller D. Reciprocating Ans. D Question 6.High % of carbon monoxide presence in the flue gas of boiler is an indicator of …………… A. Complete combustion B. Good control of pollutants C. Low excess air D. High excess air Ans. C Qu

Boiler operation engineer exam questions and answers pdf

 Boiler Operation Engineer Interview Question - 14 Q.How do you identify the leakage of economizer tube ? What is its effect ? Ans.  An economizer tube leakage can be detected by sound or increased make up water requirements. The leak should be investigated at the earliest possible time and the unit to be shut down in a normal manner. Water leaks in the economizer can cause considerable erosion damage to adjacent tubes. Water carried over from an economizer tube leak may lead to cold end corrosion also. Read More BOE Interview Questions   What are the factors which affect the Natural circulation ? What is the difference between Tower type and Two pass conventional boiler? What parameters are measured during Boiler PG test ? Why the start up vent is used in Boilers? List out the potential reasons for boiler tubes failure ?  What is cold end corrosion in boiler and When it occurs ? What is the circulation number in boiler ? Most Important Steam Blowing Questions Asked In Central BOE Inte

Boiler Operation Engineer Exam 2024

  Boiler Operation Engineer Exam Previous Year solved MCQ Set - 24 1. In pure oxygen, the maximum flame temperature is _____________ a) higher than the theoretical flame temperature b) lower than the theoretical flame temperature c) equal to the theoretical flame temperature d) none of the mentioned Ans. a 2. The heat transferred when the H2O in the products is in the liquid state is called? a) HCV b) LCV c) LHV d) None of the mentioned Ans. a 3. The maximum temperature achieved for given reactants is called? a) Practical Flame Temperature b) Critical Temperature c) Theoretical Flame Temperature d) None of the mentioned Ans. c 4. The heat transferred when the H2O in the products is in the vapour state is called? a) HCV b) LCV c) HHV d) None of the mentioned Ans. b 5. Maximum Theoretical Flame Temperature corresponds to _____________ a) Partial Combustion b) Incomplete Combustion c) Complete combustion d) None of the mentioned Ans. c 6. The maximum turbine flame temperature can be can b

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -1

Q.1 Main objective of a boiler trial is ? A. To determine the generating  capacity of the boiler B. To determine the thermal efficiency of the boiler, when working at a definite pressure C. To prepare heat balance sheet for the boiler D. All of the above Ans. D Q.2 Which super heater in a boiler has a dropping characteristics? A.Pendent super heater  B.convection super hater C. Radiant super heater D.conduction super heater Ans. C Q.3 Size of boiler tubes is specific by- A.Mean diameter and thickness B.Inside diameter and thickness C. Outside diameter & thickness D.Outside diameter alone  Ans. C You May Also Read :  Expansion and Contraction in Boilers Q.4 Reheating of steam under ideal condition takes place at constant A.Entropy B.Enthalpy C .Pressure D.Temparature Ans. C Q.5 The fusible plug in small boilers is located- A. In the drum B. In the fire tubes C. Above steam dome D. Over the combustion chamber Ans. D Q.6 Reheat cycle in steam power plant is used to- A. Prevent excess

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -2

 Question 1. Cooling towers: 1. Remove the heat from the condensate 2. Should use water treatment 3. Prevent thermal pollution of rivers and lakes 4. Cannot be used during winter periods 5. Remove the sensible heat of the steam in the condenser  A. 2, 3  B. 1, 3, 4  C. 1, 3, 4, 5   D. 3, 4, 5   E.  2, 3, 4 Ans. A Question 2.Short term overheating usually exhibits:  A. Thin lip longitudinal rupture  B.  Thick lips longitudinal rupture  C.  Transverse cracks  D.   Severe pitting Ans. A  Question 3. High Temperature stress rupture and oxidation resistant can be increased by: A.  Alloying additives of Nickel and Tin B. Alloying additives of Phosphorus and Silicone C. Alloying additives of Molybdenum and Chromium D. Alloying additives of Aluminium and Boron Ans. C Question 4. Which of the following boilers has emerged as an alternative to conventional boilers because of its higher combustion efficiency? A. Fluidised bed combustion boiler B. Packaged boiler C. Stoker fired boiler D. Chain gr

Maharashtra Boiler Exam 2024 Notification

  Boiler Operation Engineer Previous year Questions With Answer Set - 41 1. Assuming same efficiency for the same draught and neglecting leakage, power required by induced draught fan is greater than power required by forced draught fan. a) True b) False Ans. a 2. Which of the following is FALSE about steam jet draught? a) Low grade fuel can also be used b) Requires low maintenance c) Steam jet draught is a type of artificial draught d) In case of forced steam jet draught, the jet is directed into smoke box Ans. d 3. Which of the following statements is FALSE regarding artificial draught? a) There is no need of water cooled bearing in forced draught fan b) Fan size and power required by a forced draught fan are 1/5 to ½ of that required for an induced draught fan c) Tendency for air leak into the boiler furnace is less in Induced draught fan as compared to forced draught fan d) In forced draught the fan/blower is installed near the base of the boiler Ans. c 4. Which of the following st