Skip to main content

Boiler Feed Water Pump Operation Questions For Power Plant Interview

 Boiler Feed Water Pump  Operation Questions 

1.What do you mean by NPSHA & NPSHR in BFPs?
NPSHA: Net positive suction head available is the absolute pressure at the suction port of the pump.
NPSHR: Net positive suction head required is the minimum pressure required at the suction port of the pump to prevent the pump from cavitations.
NPSHA should be always greater than NPSHR (NPSHA >  NPSHR)
2.How do cavitations occur? What are the abnormal effects of cavitations?
Pump cavitation occurs when the pressure in the pump inlet drops below the vapour pressure of the liquid. Vapour bubbles form at the inlet of the pump and are moved to the discharge of the pump where they collapse and make high sound and vibrations often taking small pieces of the pump with them.

Cavitation is often characterized by:

  • Loud noise often described as a grinding or “marbles” in the pump.
  • Loss of capacity (bubbles are now taking up space where liquid should be).
  • Pitting damage to parts as material is removed by the collapsing bubbles.
3.What do you mean by the shut off  pressure in centrifugal pumps?
Shut-off head is a condition, when a centrifugal pump runs with discharge valve closed. It is the maximum head generated by a centrifugal pump with  zero flow and relatively less power.
4.Why the BFP discharge water & balance leak off temperature is slightly more than that of suction water temperature?
Due to the compression action of water inside the pump, the water temperature rises around 2 to 3 deg C more than the suction water. Water is an in compressible fluid.
5.What is the velocity of water in the balance leak off line?
It should not exceed 5 m/sec on any account
6.How do you calculate the maximum allowable balance leak off pressure?
Maximum allowable balance leak off pressure = 0.03X (Shut off pressure-Suction pressure)+ Suction pressure.
7.What does it indicate if balance pressure is increasing gradually?
It indicates the wear out of balance or counter balance disc. That is gap or clearance between these two discs has increased
8.What is the operating pressure of balance leak off line ?


It is just 0.5 to 1 kg/cm2 more than pump’s suction pressure
9.What is the significance of NPSH in BFPS?
If BFPs do not have required NPSH, then there will be more chances for formation of cavitations.
10.How the pump speed is related to NPSH?
NPSHR varies approximately with the square of pump speed.
NPSHR = N2
11.Why the balance leak off line water is not connected to suction line to save the pump hydraulic power instead of directing it into Deaerator?
Balance leak off water temperature is little bit higher than pump operating temperature which may lead cavitations if it mixes with suction water. For some pumps where there is no risk of cavitations, in such cases this line is connected to suction side of the pump.
12.What is the function of balance leak off line?
Balance leak off line is used to balance the centrifugal pump shaft from axial thrust. During centrifugal pump operation, especially in multistage centrifugal, suction side will have relatively very less pressure as compared to the discharge side. Because of this, there are lot of possibilities that impeller along with the shaft and bearing will be pushed from discharge end to suction end which is also known as axial thrust. Balance line is used to balance the centrifugal pump shaft from axial thrust. Due to the axial thrust, pump bearings and internals will get damaged. To nullify this effect, a tapping from discharge end (between balancing & counter balancing disc) is connected to a balancing drum.
13.What is the function minimum re circulation line or Automatic re circulation valve ?
Minimum re circulation line is provided mainly for centrifugal pump with constant speed drive based on the system and vendor information. There are two types of minimum continuous flow required by the pump (Stable and Thermal). Pump is designed to operate at the flow greater than this flow rate. If pump is operated at less flow than the minimum continuous stable flow, it will damage bearing and internals and may abnormal vibration occur. Below the minimum continuous thermal flow, temperature of fluid will rise at faster rate. To avoid these problems, minimum re circulation line is provided. If the demand of the fluid is decreased below minimum continuous flow, then the auto re circulation valve of the pump will open and maintains the required flow and if flow increased more than minimum flow then auto re circulation valve closes. Generally for higher head flow like 1500 meter head pump the minimum circulation will be 20–25% of total capacity.
14.What are the different protection devices given for boiler feed pumps?
  • Pressure relief valve
  • Balance leak off line
  • Auto re circulation valve
  • 15.What is the size of suction strainer of a BFP ?
  • It is generally 30 to 40 mesh, that is 30 or 40 hole openings in 1 linear inch on strainer.
  • A SS 30 wire mesh is generally wrapped on SS mesh having hole openings around 3 to 4 mm
16.What are the various pipe lines connected to BFP?
  • Suction pipe line
  • Discharge pipe line
  • Bearing cooling water lines
  • Jacket cooling water lines
  • Mechanical seal flushing line
  • ARC line (Minimum re circulation line)
  • Impulse lines for instrumentation measurements (Suction pressure, discharge pressure, Differential pressure, balance leak off pressure)
  • Balance leak off line
17.What are the auxiliaries associated with BFP?
BFP auxiliaries
  • Cooling water pump & lines
  • Lube oil system
  • ARC valve
  • Mechanical seal flushing system
  • Balance leak off line & its PRV
18.What are the type of prime movers (drives) used for BFPs?
Prime movers:
  • LT drive (415 V)
  • HT drive (11 KV)
  • Turbo drive (Steam driven)
19.What is the function of Boiler feed pumps (BFP) in power plant?
  • To supply the feed water to boilers
  • To conduct the Boiler hydraulic tests
  • To supply the desuperheating & attemperator water required for process steam lines & boilers respectively
20.What are the protection interlocks given for BFPs ?.
Protection interlocks: That is BFP will trip/stop on following conditions
  • Low Deaerator level
  • High bearing vibrations
  • High bearing temperature
  • Low cooling water pressure
  • More differential pressure of suction strainer
  • High load
  • Higher balance leak off pressure
  • Low speed (<40% of rated speed)

Also Read :

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -1

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -2

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -3

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -4 

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -5

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -6

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -7

BOE (Boiler Operation Engineer) Previous Year Exam Questions And Answers Set - 8

Most Important Post :

How to calculate suction head in centrifugal pump

Top 16 Power System Interview Questions 

Boiler Feed Pump (B.F.P) Starting Procedure In Thermal Power Plant

Types of Mechanical Seals in Pump 

Why pumps are used in parallel and series mode of operations ?

What is priming of a centrifugal pump and why it is required 

What are the types of pumps | Classification of pumps - interview questions

Gland Seal vs. Mechanical Seal 

What is the function of volute casing in centrifugal pump?

To See Power Plant Interview Related Videos Click Below 

Click here 




Comments

Popular posts from this blog

BOE Exam ( Boiler Operation Engineer ) Solved Papers Set - 21

Boiler Operation Engineer (BOE) Previous Year Questions With Answer - 21 1. What is the solubility of dissolved gases at boiling or saturation temperature? a) Positive b) Negative c) Zero d) None of the mentioned Ans. c 2. In the deaerator, the feedwater is heated to the saturation temperature by the steam extracted from? a) compressor b) turbine c) pump d) none of the mentioned Ans. b 3. Which of the following type heater is known as deaerator? a) Contact-type open heater b) Contact-type closed heater c) Closed heater d) None of the mentioned Ans. a 4. Where is the deaerator placed in the feedwater system? a) in the beginning b) in the middle c) at the end d) there is no deaerator in the feedwater system Ans. b 5. Which among the following goes to the Vent Condenser along with Oxygen & Carbon dioxide? a) Sodium sulphite b) Carbon monoxide c) Water vapour d) None of the mentioned Ans. c 6. Why is the deaerator not employed in water cooled & moderated nuclear power plant? a) due...

Boiler interview questions and answers pdf

 Boiler Operation Engineer Interview Question - 16 Q.No-1. Can the blades of FD fan be replaced by  the ID fan blades?  Ans. Yes, but the power consumption will increase and motor will be unnecessarily overloaded. Q.No-2. What is the function of pitch control mechanism? Ans. To vary the blade angle of FD and ID fan, in order to vary the quantity of air flow across the fan by means of hydraulic servomotor. Q.No-3. For what purpose dampers are used and where these are located ? Ans.  a) Dampers are used to start the FD and ID fan at no load condition b) During maintenance to keep it is isolate condition Q.No-4. Which economizer is best one and Why it so ? Ans. Non steaming type economizer is the best one. Reasons   a.) It enhance the natural circulation b.) Effective utilization of heat carried away by the flue gas is recovered for preheating the air in RAPH  c.) Efficiency of the boiler will increase Q.No-5. What is Natural circulation? How it takes pl...

Classification of Steam Condensers - Boiler inspector exam question papers

 1. Which of the following statements is FALSE about double-pass condensers? a) The water flows in one direction through some tubes and returns through the remainder b) Exhaust steam flows through the tubes, while cooling water passes over the outer surface of the tubes c) It is a type of surface condenser d) Cooling water doesn’t come in contact with the exhaust steam Ans. b 2. Which of the following statements is False about steam condensers? a) Jet condensers are cheaper than surface condensers b) Cooling water comes direct contact with the exhaust steam in jet condensers c) Cooling water does not come in direct contact with exhaust steam in surface condensers d) Jet condensers are further classified into single-pass and double-pass condensers Ans. d 3. Which of the following statements is TRUE about single-pass condenser? a) It is a type of jet Condenser b) The flow of water is in one direction only c) The water flows in one direction through some tubes and returns through the ...

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -1

Q.1 Main objective of a boiler trial is ? A. To determine the generating  capacity of the boiler B. To determine the thermal efficiency of the boiler, when working at a definite pressure C. To prepare heat balance sheet for the boiler D. All of the above Ans. D Q.2 Which super heater in a boiler has a dropping characteristics? A.Pendent super heater  B.convection super hater C. Radiant super heater D.conduction super heater Ans. C Q.3 Size of boiler tubes is specific by- A.Mean diameter and thickness B.Inside diameter and thickness C. Outside diameter & thickness D.Outside diameter alone  Ans. C You May Also Read :  Expansion and Contraction in Boilers Q.4 Reheating of steam under ideal condition takes place at constant A.Entropy B.Enthalpy C .Pressure D.Temparature Ans. C Q.5 The fusible plug in small boilers is located- A. In the drum B. In the fire tubes C. Above steam dome D. Over the combustion chamber Ans. D Q.6 Reheat cycle in steam power plant is use...

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -2

 Question 1. Cooling towers: 1. Remove the heat from the condensate 2. Should use water treatment 3. Prevent thermal pollution of rivers and lakes 4. Cannot be used during winter periods 5. Remove the sensible heat of the steam in the condenser  A. 2, 3  B. 1, 3, 4  C. 1, 3, 4, 5   D. 3, 4, 5   E.  2, 3, 4 Ans. A Question 2.Short term overheating usually exhibits:  A. Thin lip longitudinal rupture  B.  Thick lips longitudinal rupture  C.  Transverse cracks  D.   Severe pitting Ans. A  Question 3. High Temperature stress rupture and oxidation resistant can be increased by: A.  Alloying additives of Nickel and Tin B. Alloying additives of Phosphorus and Silicone C. Alloying additives of Molybdenum and Chromium D. Alloying additives of Aluminium and Boron Ans. C Question 4. Which of the following boilers has emerged as an alternative to conventional boilers because of its higher combustion efficiency? A. F...

BOE (Boiler Operation Engineer) Previous Year Exam Questions And Answers Set - 8

Question 1.The capacity of induced draft fan compared to forced draft fan in a boiler is ………. A. Same B. More C. Less D. Depending upon size of boiler Ans. B Question 2.O2 content in atmospheric air on volume basis is ………… A. 21% B. 23% C. 30% D. 78% Ans. A Question 3.Scale is formed on heat transfer surface when……………….. A. Water is acidic B. Water is alkaline C. Water contains dissolved gases D. Water contains dissolved calcium and magnesium salts. Ans. D Question 4.Which one of the following fuel has the highest hydrogen content and lowest sulphur content …………… A. Coal B. Furnace oil C. Natural gas D. LSHS Ans. C Question 5.For boiler water treatment chemical dosing with small discharge at high pressure, pump preferred is ………… A. Centrifugal B. Axil flow C. Propeller D. Reciprocating Ans. D Question 6.High % of carbon monoxide presence in the flue gas of boiler is an indicator of …………… A. Complete combustion B. Good control of pollutants C. Low excess air D. High excess air Ans. C Qu...

Boiler operation engineer exam questions and answers pdf

 Boiler Operation Engineer Interview Question - 14 Q.How do you identify the leakage of economizer tube ? What is its effect ? Ans.  An economizer tube leakage can be detected by sound or increased make up water requirements. The leak should be investigated at the earliest possible time and the unit to be shut down in a normal manner. Water leaks in the economizer can cause considerable erosion damage to adjacent tubes. Water carried over from an economizer tube leak may lead to cold end corrosion also. Read More BOE Interview Questions   What are the factors which affect the Natural circulation ? What is the difference between Tower type and Two pass conventional boiler? What parameters are measured during Boiler PG test ? Why the start up vent is used in Boilers? List out the potential reasons for boiler tubes failure ?  What is cold end corrosion in boiler and When it occurs ? What is the circulation number in boiler ? Most Important Steam Blowing Questions A...

What is RAPH & SCAPH and their functions in Boiler ? - BOE Exam Questions And Answers

  Boiler Operation Engineer ( BOE ) Interview Question - 31 Q.What is RAPH & SCAPH and their functions ? Ans.  Regenerative Air Preheater ( RAPH ) : Regenerative air pre heater (RAPH) is mainly used for preheating the FD fan outlet air by utilising the outgoing flue gas temperature for making the combustion a rapid and efficient one. Steam Coil Air Preheater : Steam coil air pre heater (SCAPH) is employed mainly during start up. As during start up, the flue gas temperature at the inlet of RAPH will be less. If the air extracts more heat from the flue gas, the flue gas temperature falls below 140°C and it leads to cold end corrosion. So to avoid this air is preheated by SCAPH to that steam supplied from the AST header. So that heat transfer rate in RAPH can be reduced without allowing flue gas temperature to fall below 140C. The SCAPH is located after FD fan outlet and before RAPH.  Read More Boiler Interview Questions   What are the factors which affect the ...