Skip to main content

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -2

 Question 1. Cooling towers: 1. Remove the heat from the condensate 2. Should use water treatment 3. Prevent thermal pollution of rivers and lakes 4. Cannot be used during winter periods 5. Remove the sensible heat of the steam in the condenser

 A. 2, 3

 B. 1, 3, 4

 C. 1, 3, 4, 5

  D. 3, 4, 5

  E.  2, 3, 4

Ans. A

Question 2.Short term overheating usually exhibits:

 A. Thin lip longitudinal rupture

 B.  Thick lips longitudinal rupture

 C.  Transverse cracks

 D.   Severe pitting

Ans. A 

Question 3. High Temperature stress rupture and oxidation resistant can be increased by:

A.  Alloying additives of Nickel and Tin

B. Alloying additives of Phosphorus and Silicone

C. Alloying additives of Molybdenum and Chromium

D. Alloying additives of Aluminium and Boron

Ans. C

Question 4. Which of the following boilers has emerged as an alternative to conventional boilers because of its higher combustion efficiency?

A. Fluidised bed combustion boiler

B. Packaged boiler

C. Stoker fired boiler

D. Chain grate boiler

Ans. A

Question 5. Fluidised bed combustion has _______________ effect on Sox and Nox emissions

A. Increased

B. No effect

C. Decreased

D. Depends on type of solid fuel used

Ans. C

Question 6. The largest has loss from boiler are caused by

A. Moisture in fuel

B. Radiation and convection

C. Moisture in air

D. Dry flue gas

Ans. D

Question 7. An increase in the conductivity of the water inside the boiler indicates a rise in

A. Purity

B. Temperature

C. Contamination

D. None of the above

Ans. C

Question 8. Long term overheating exhibits:

A. Thin lip longitudinal rupture

B. Transverse cracks

C. Thick lip longitudinal rupture

D. Severe pitting

Ans. C

Question 9.Creep damage can be detected with:

A. Changes in tube wall thickness

B. Severe bulging of tube wall

C. Micro structure examination of iron carbides

D. Transverse cracking of tube wall 

Ans. C

Question 10. The efficiency of a typical FBC boiler is of the order of

A. 30 %

B. 80 %

C. 70 %

D. 40%

Ans. B

Also Read :

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -1

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -3

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -4 

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -5

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -6

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -7

BOE (Boiler Operation Engineer) Previous Year Exam Questions And Answers Set - 8

You May Also Like

What is pump losses ? | What type of losses exists inside the centrifugal pump?

Boiler Feed Water Pump  Operation Questions For Power Plant Interview

How to calculate suction head in centrifugal pump

Top 16 Power System Interview Questions 

Boiler Feed Pump (B.F.P) Starting Procedure In Thermal Power Plant

Types of Mechanical Seals in Pump 

Why pumps are used in parallel and series mode of operations ?

What is priming of a centrifugal pump and why it is required 

What are the types of pumps | Classification of pumps - interview questions

Gland Seal vs. Mechanical Seal 

What is the function of volute casing in centrifugal pump?


To See Power Plant Interview Related Videos Click Below 

Click here 



Comments

Popular posts from this blog

BOE Exam ( Boiler Operation Engineer ) Solved Papers Set - 21

Boiler Operation Engineer (BOE) Previous Year Questions With Answer - 21 1. What is the solubility of dissolved gases at boiling or saturation temperature? a) Positive b) Negative c) Zero d) None of the mentioned Ans. c 2. In the deaerator, the feedwater is heated to the saturation temperature by the steam extracted from? a) compressor b) turbine c) pump d) none of the mentioned Ans. b 3. Which of the following type heater is known as deaerator? a) Contact-type open heater b) Contact-type closed heater c) Closed heater d) None of the mentioned Ans. a 4. Where is the deaerator placed in the feedwater system? a) in the beginning b) in the middle c) at the end d) there is no deaerator in the feedwater system Ans. b 5. Which among the following goes to the Vent Condenser along with Oxygen & Carbon dioxide? a) Sodium sulphite b) Carbon monoxide c) Water vapour d) None of the mentioned Ans. c 6. Why is the deaerator not employed in water cooled & moderated nuclear power plant? a) due

Boiler interview questions and answers pdf

 Boiler Operation Engineer Interview Question - 16 Q.No-1. Can the blades of FD fan be replaced by  the ID fan blades?  Ans. Yes, but the power consumption will increase and motor will be unnecessarily overloaded. Q.No-2. What is the function of pitch control mechanism? Ans. To vary the blade angle of FD and ID fan, in order to vary the quantity of air flow across the fan by means of hydraulic servomotor. Q.No-3. For what purpose dampers are used and where these are located ? Ans.  a) Dampers are used to start the FD and ID fan at no load condition b) During maintenance to keep it is isolate condition Q.No-4. Which economizer is best one and Why it so ? Ans. Non steaming type economizer is the best one. Reasons   a.) It enhance the natural circulation b.) Effective utilization of heat carried away by the flue gas is recovered for preheating the air in RAPH  c.) Efficiency of the boiler will increase Q.No-5. What is Natural circulation? How it takes place? Ans. It is defined as t

BOE (Boiler Operation Engineer) Previous Year Exam Questions And Answers Set - 8

Question 1.The capacity of induced draft fan compared to forced draft fan in a boiler is ………. A. Same B. More C. Less D. Depending upon size of boiler Ans. B Question 2.O2 content in atmospheric air on volume basis is ………… A. 21% B. 23% C. 30% D. 78% Ans. A Question 3.Scale is formed on heat transfer surface when……………….. A. Water is acidic B. Water is alkaline C. Water contains dissolved gases D. Water contains dissolved calcium and magnesium salts. Ans. D Question 4.Which one of the following fuel has the highest hydrogen content and lowest sulphur content …………… A. Coal B. Furnace oil C. Natural gas D. LSHS Ans. C Question 5.For boiler water treatment chemical dosing with small discharge at high pressure, pump preferred is ………… A. Centrifugal B. Axil flow C. Propeller D. Reciprocating Ans. D Question 6.High % of carbon monoxide presence in the flue gas of boiler is an indicator of …………… A. Complete combustion B. Good control of pollutants C. Low excess air D. High excess air Ans. C Qu

Boiler operation engineer exam questions and answers pdf

 Boiler Operation Engineer Interview Question - 14 Q.How do you identify the leakage of economizer tube ? What is its effect ? Ans.  An economizer tube leakage can be detected by sound or increased make up water requirements. The leak should be investigated at the earliest possible time and the unit to be shut down in a normal manner. Water leaks in the economizer can cause considerable erosion damage to adjacent tubes. Water carried over from an economizer tube leak may lead to cold end corrosion also. Read More BOE Interview Questions   What are the factors which affect the Natural circulation ? What is the difference between Tower type and Two pass conventional boiler? What parameters are measured during Boiler PG test ? Why the start up vent is used in Boilers? List out the potential reasons for boiler tubes failure ?  What is cold end corrosion in boiler and When it occurs ? What is the circulation number in boiler ? Most Important Steam Blowing Questions Asked In Central BOE Inte

Boiler Operation Engineer Exam 2024

  Boiler Operation Engineer Exam Previous Year solved MCQ Set - 24 1. In pure oxygen, the maximum flame temperature is _____________ a) higher than the theoretical flame temperature b) lower than the theoretical flame temperature c) equal to the theoretical flame temperature d) none of the mentioned Ans. a 2. The heat transferred when the H2O in the products is in the liquid state is called? a) HCV b) LCV c) LHV d) None of the mentioned Ans. a 3. The maximum temperature achieved for given reactants is called? a) Practical Flame Temperature b) Critical Temperature c) Theoretical Flame Temperature d) None of the mentioned Ans. c 4. The heat transferred when the H2O in the products is in the vapour state is called? a) HCV b) LCV c) HHV d) None of the mentioned Ans. b 5. Maximum Theoretical Flame Temperature corresponds to _____________ a) Partial Combustion b) Incomplete Combustion c) Complete combustion d) None of the mentioned Ans. c 6. The maximum turbine flame temperature can be can b

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -1

Q.1 Main objective of a boiler trial is ? A. To determine the generating  capacity of the boiler B. To determine the thermal efficiency of the boiler, when working at a definite pressure C. To prepare heat balance sheet for the boiler D. All of the above Ans. D Q.2 Which super heater in a boiler has a dropping characteristics? A.Pendent super heater  B.convection super hater C. Radiant super heater D.conduction super heater Ans. C Q.3 Size of boiler tubes is specific by- A.Mean diameter and thickness B.Inside diameter and thickness C. Outside diameter & thickness D.Outside diameter alone  Ans. C You May Also Read :  Expansion and Contraction in Boilers Q.4 Reheating of steam under ideal condition takes place at constant A.Entropy B.Enthalpy C .Pressure D.Temparature Ans. C Q.5 The fusible plug in small boilers is located- A. In the drum B. In the fire tubes C. Above steam dome D. Over the combustion chamber Ans. D Q.6 Reheat cycle in steam power plant is used to- A. Prevent excess

Maharashtra Boiler Exam 2024 Notification

  Boiler Operation Engineer Previous year Questions With Answer Set - 41 1. Assuming same efficiency for the same draught and neglecting leakage, power required by induced draught fan is greater than power required by forced draught fan. a) True b) False Ans. a 2. Which of the following is FALSE about steam jet draught? a) Low grade fuel can also be used b) Requires low maintenance c) Steam jet draught is a type of artificial draught d) In case of forced steam jet draught, the jet is directed into smoke box Ans. d 3. Which of the following statements is FALSE regarding artificial draught? a) There is no need of water cooled bearing in forced draught fan b) Fan size and power required by a forced draught fan are 1/5 to ½ of that required for an induced draught fan c) Tendency for air leak into the boiler furnace is less in Induced draught fan as compared to forced draught fan d) In forced draught the fan/blower is installed near the base of the boiler Ans. c 4. Which of the following st