NCP BOE Interview Question - What is the difference between Tower type and Two pass conventional boiler?

What is difference between Tower type and Two pass conventional boiler?

Ans. 

Tower Type

1.All the boiler pressure parts are arranged single column

2. Height of the boiler is more

3. Drum is at 80 m level

4.The pressure parts are arranged in horizontal manner

Two pass

1.The boiler pressure parts arranged in two columns
2.Height of the boiler is less
3.Drum is at 50 m level
4.The pressure parts are arranged in both vertical and in horizontal manner

Also Read :

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -1

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set - 2

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -3

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -4

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -5

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -6

Boiler Operation Engineer ( BOE ) Previous Year Multiple Choice Questions With Answer Set -7

You May Also Like :

Water Chemistry Interview Question With Answer 

Boiler Feed Pump Interview Question With Answer 

What are the types of pump ?

Coolant and lubricant

How to calculate suction head in centrifugal pump

Top 16 Power System Interview Questions 

Boiler Feed Pump (B.F.P) Starting Procedure In Thermal Power Plant

Types of Mechanical Seals in Pump 

Why pumps are used in parallel and series mode of operations ?

What is priming of a centrifugal pump and why it is required 

Gland Seal vs. Mechanical Seal 

What is the function of volute casing in centrifugal pump?

To See Power Plant Interview Related Videos Click Below 

Click here 


Comments